Guide to Code Compliant HVAC Plans

Residential HVAC plans and permit documentation

What makes residential HVAC plans code-compliant?

A code-compliant HVAC plan set connects the home’s calculated loads to the selected equipment and the duct system, then documents the assumptions clearly enough for the local reviewer and installer to follow.

Direct answer: For many residential projects, the core design path is a Manual J load calculation, followed by Manual S equipment selection, with Manual D duct design when duct sizing and distribution documentation are required. The exact submittal still depends on the code edition and the local authority having jurisdiction.

Residential Manual J project summary showing heating load, sensible cooling load, latent cooling load, design conditions, infiltration, and equipment sizing information.
A useful permit package shows more than a tonnage number. It documents the building inputs, calculated loads, equipment decision, and—when applicable—the airflow and duct design.
Manual JCalculates room and whole-house loads
Manual SMatches equipment to those loads
Manual DDesigns the residential duct system
Local reviewFinal requirements vary by jurisdiction
The central idea

Code compliance is a chain, not a single report.

A load calculation can be accurate and still leave the project incomplete if the equipment was never checked against manufacturer data or the duct system cannot deliver the required airflow.

Step 1

Manual J: determine the building loads

The home is modeled using location, orientation, construction assemblies, insulation, glazing, infiltration, ventilation, ducts, and internal gains. The result should include both whole-house and room-by-room loads when room airflow is part of the design.

How Manual J works →
Step 2

Manual S: select actual equipment

Nominal tonnage is not enough. Manual S uses manufacturer performance data to verify heating capacity, total cooling capacity, sensible cooling capacity, latent performance, and airflow at the project’s design conditions.

How Manual S works →
Step 3

Manual D: design the ducts

Manual D uses room airflow requirements, blower data, available static pressure, fitting losses, duct lengths, and the selected equipment airflow to size the supply and return system.

How Manual D works →

Why this order matters: Manual S cannot repair an inaccurate Manual J, and Manual D cannot deliver room-by-room comfort if the equipment airflow and room loads were never established.

Permit package workflow

How a residential HVAC plan set comes together.

01

Review the plans

Floor plans, elevations, sections, schedules, location, orientation, and construction details are checked for conflicts or missing information.

02

Model the home

Rooms, walls, windows, ceilings, floors, exposure, infiltration, ventilation, and duct conditions are entered into the calculation software.

03

Calculate loads

Heating, sensible cooling, latent cooling, and room-by-room airflow requirements are documented through Manual J.

04

Select equipment

Manufacturer data is compared with the loads using Manual S rather than choosing equipment by nominal size alone.

05

Design and document

Duct sizes, airflow, equipment schedules, notes, and reports are assembled according to the project scope and reviewer requirements.

What reviewers commonly need

What should be included in residential HVAC plans?

The answer depends on the jurisdiction, project type, and adopted code. A useful residential HVAC package commonly includes enough information to verify that the building load, equipment, and distribution system agree with one another.

  • Project address and climate/design location
  • Indoor and outdoor design conditions
  • Building orientation and room geometry
  • Wall, roof, ceiling, floor, window, and door assumptions
  • Infiltration and ventilation inputs
  • Whole-house heating and cooling loads
  • Room-by-room loads and airflow where required
  • Manual S equipment selection information
  • Manufacturer model numbers and performance data
  • Duct sizes, airflow, and design criteria when included
  • Supply and return locations or schedules when required
  • Notes identifying assumptions and project limitations

Do not assume every permit office wants the same package. One jurisdiction may accept Manual J and Manual S reports, while another may also require duct plans, ventilation documentation, equipment schedules, energy forms, or locally formatted worksheets. Confirm the local checklist before treating any national template as complete.

Residential Manual D duct layout showing supply and return duct routes, room airflow assignments, and duct sizing information.
A duct layout becomes meaningful when its airflow assignments trace back to the room-by-room load calculation and the selected equipment.
The difference between reports

What each document proves—and what it does not.

DocumentPrimary questionWhat it should showWhat it does not replace
Manual JWhat are the heating and cooling loads?Building inputs, design conditions, whole-house and room loads, sensible and latent coolingEquipment performance verification
Manual SDoes the proposed equipment match the loads?Manufacturer performance at design conditions, heating capacity, sensible and total cooling capacityDuct sizing and room airflow delivery
Manual DCan the system deliver the required airflow?Airflow assignments, available pressure, effective length, duct sizes, fittings, supply and return designThe load calculation or equipment selection
Mechanical planHow is the selected system represented on the project documents?Equipment, ducts, grilles, notes, schedules, ventilation, and project-specific detailsThe supporting calculations behind the plan
Manual S compliance report showing residential HVAC equipment performance compared with calculated heating, sensible cooling, and latent cooling loads.
Manual S checks actual performance—not just the nominal size printed on the equipment label.
Common reasons for rejection or revision

Why HVAC plans get questioned.

Mismatch

The equipment does not match the calculation.

The plan lists equipment, but there is no Manual S documentation—or the selected capacity does not align with the heating, sensible, and latent loads.

Missing inputs

The report cannot be traced to the plans.

Orientation, glazing, assemblies, ventilation, duct location, or design conditions are missing, contradictory, or clearly inconsistent with the construction documents.

Incomplete distribution

The ducts are shown without design support.

Room airflow, available static pressure, fitting losses, return-air strategy, or duct sizes are not connected to a documented Manual D process.

A clean drawing is not automatically a compliant design. The drawings and reports must agree. If the load calculation, equipment schedule, and duct plan point to different systems or airflow values, formatting will not solve the underlying conflict.

Software and judgment

Approved software is necessary. Good inputs are still the deciding factor.

Professional load-calculation software applies the formulas, tables, weather data, and procedures required by the selected method. It can organize room loads, equipment data, and duct calculations far more efficiently than a manual worksheet.

It still cannot decide whether a plan note overrides a schedule, whether the north arrow is wrong, whether an attic is truly inside the conditioned envelope, or whether the ventilation assumptions match the mechanical scope. Those are review decisions.

That is why the quality of a code submittal depends on both the software and the human interpretation of the project information.

Our workflow: We use Wrightsoft for residential load calculations, equipment selection, and duct-design work. The reports are built from the project plans and known construction information, with assumptions identified when the plans do not answer a required question.

Three-dimensional residential load calculation model used to verify room geometry, windows, walls, ceilings, floors, and room-by-room HVAC loads.
The model provides the connection between the architectural plans and the calculated loads shown in the final reports.
Frequently asked questions

Code-compliant HVAC plans FAQ

What are code-compliant HVAC plans?

Code-compliant HVAC plans are project documents and supporting calculations prepared to meet the adopted residential code and the local review requirements. They commonly connect Manual J loads, Manual S equipment selection, and Manual D duct design, but the exact submittal varies by jurisdiction.

Are Manual J, Manual S, and Manual D always required?

They are widely referenced in residential codes and permit processes, but the exact documentation required for a specific project depends on the adopted code, project type, and local authority having jurisdiction. Confirm the local checklist before submitting.

Can a Manual J report be used without Manual S?

A Manual J report establishes the loads, but it does not by itself prove that a proposed equipment model matches those loads. Manual S is the equipment-selection step that compares manufacturer performance data with the calculated requirements.

Does a duct drawing automatically satisfy Manual D?

No. A drawing can show duct routes without documenting room airflow, available static pressure, total effective length, fitting losses, duct sizes, or the calculation process used to reach those sizes. Manual D is the design method behind the drawing.

What information is needed to prepare residential HVAC plans?

Typical inputs include floor plans, elevations, sections, window and door schedules, insulation and assembly details, project location, orientation, ventilation information, equipment preferences, and any permit checklist supplied by the local jurisdiction.

Can one plan set work for every jurisdiction?

No universal plan set is guaranteed to satisfy every reviewer. National methods provide the design foundation, but local jurisdictions can require specific forms, notes, equipment schedules, energy documents, ventilation information, or drawing conventions.

How do I start a permit-plan project?

Use the pricing and project-start page to choose the needed Manual J, Manual S, or Manual D service and submit the available plans. Include the local permit checklist when one is available.

Related resources

Continue through the residential design process.

Manual D

Duct sizing, airflow distribution, static pressure, and effective length.

Explore Manual D →
Heat Gain and Heat Loss

Understand where the calculated loads come from in a residential building.

Understand the loads →
Areas Served

Climate-specific residential load-calculation resources across the United States.

Browse areas served →
Ready to submit plans?

Build the permit package from the building outward.

Send the plans, construction details, equipment information, and any local permit checklist. We will review the scope and prepare the selected residential Manual J, Manual S, and Manual D documents.

See pricing and upload plans
Scroll to Top